[Skip to content]

Federation of Master Builders logo
.

Cannon Preservation

200 Harwich Road, Colchester, Essex, CO4 3DE
 
  • Woodworm, Dry Rot and Damp Course Specialists
  • Wall Tie Replacement Contrator

Ask Cannon Preservation to quote for your job

Request quote
The easiest way to find a tradesperson for your project is to use our Find A Builder service. We have thousands of vetted members nationwide.
  • Have had an inspection on a job in progress on joining
  • Has a minimum of twelve months trading
  • Have provided a professional reference
  • Have passed credit checks, public record and director checks
  • Verified no un-discharged bankruptcies or relevant and outstanding County Court Judgments
  • Has Public and Employer (if applicable) Liability Insurance
  • VAT registration (if applicable)
  • Confirmation of business address/details
  • Cannon Preservation has agreed to abide by the FMB Disputes Resolution and Complaints Procedures
  • Has signed up to the FMB Code of Practice
  • Can offer the suite of Build Assure warranty products for the domestic and commercial markets (contact the Build Assure office for rates)

Member Profile

Member image

Cannon Preservation offer a comprehensive range of specialist property and environmental services to both domestic and commercial customers across the south east of England. From damp proofing and woodworm treatment to rising damp control and Waterproofing membrane systems.If your property is in need of Remedial Treatments then we can help,working in Property Care and the Remedial Industry since 1997 we are sure we can offer a solution to your property and families needs.
We also offer a Guarantee for remedial treatments: Damp proofing,Timber preservation,specialist plastering and basement waterproofing systems.

Cannon Preservation also offer insured guarantees provided by CGS ltd for a small one off fee, covering Damp proof coursing,Timber/Woodworm treatments,Specialist plastering and Cavity wall ties for a term of 20 years. Also we offer Insured guarantees for structural waterproofing systems, also provided through CGS ltd for a term of 10 years.

Cannon Preservation offers various services as listed below and has the experience and expertise to ensure that your property remains safe, stable and attractive.

 

 

 


Our services cover the following:

 

  • Waterproof Membrane Systems
  • Basement Waterproofing
  • Cellar Waterproofing
  • Rising Damp Control
  • Damp Proofing
  • Plastering/Tanking
  • Dry Rot Control
  • Woodworm Treatment
  • Timber Care/Repair
  • Timber Resin Repairs
  • Crack Stitch Repairs
  • Cavity Wall Tie Replacement
  • CPDs

Member of ; 

FMB

Trust Mark

Safe Contractor

Norfolk Trusted Traders

Construction Guarantee Services ltd

We work extensively throughout Essex and Suffolk but also border london and norfolk for various clients.


Cannon Preservation also offer FREE Surveys and Estimates within a 40 mile radius of Colchester.




Case Study 1

Cavity wall ties and Crack stitch repairs.

This is a project involving Crack Stitch Repairs and Cavity Wall Ties Renewal and Isolation.Property is of around a 100 years old and built of Red Stock Bricks and very close to the sea.
Sea salts appart from driving rain can cause alot of damage to timber and steel fixings,once the moisture enters the outer leaf it can then start causing issues to the Wall Ties and move around the cavity.

Property was Surveyed in April 2011 and found to have a large crack to Gable end of around 3 metres in height and around 250mm to 500mm from corner/Buttress of property.Cause was due to Cavity Wall Ties corroding and causing vertical cracking in a fork like fashion,wall ties were Fishtail ties and due to the steel Corrosion and rusting they expand and cause damage to surrounding brickwork.


Work started on 9-5-2011 and completed on 16-5-2011 on Gable end only.


Works involved were Crack Stitch Repairs over the 3 metres in height and as per photos it involved Grinding the mortar bed every four courses(13 in total) at 60mm deep and using Helical Stainless Steel Bars inbedded into a 10mm/20mm bed of Resin Compound and then repointed,all cracked brickwork was either replaced or repaired with a grout to a similar colour.

Cavity Wall Ties: Wall ties to Gable end were found to be Corroded and or Rusty to about 90% and in need of replacing and isolating.All Wall Ties were located using a metal detector then mortar was removed around the Ties by meens of a angle grinder and then all ties were isolated using a Clam/Sleeve to stop any more moisture to affect the Steel and cause any more expanssion. New Ties were introduced by Drilling into both leaves and being the cavity was 75mm the Wall Ties were 220mm Helical and Stainless Steel.With a fixing of no less than 50mm into the inner leaf these were then Resin fixed due to the soft Stock and Lime mortar mix for a better fixture,outer leaf was a dencer mix of sand,cement and clinker mix and also resin fixed.

Case study one picture 1
Case study one picture 2