At The Flat Roofing Company we take pride in providing our customers with a friendly, professional standard of service. Specialising in single ply flat roofing ~ We install high spec membranes onto a variety of surfaces creating modern waterproof roofs. Our team is fully insured, with a …
Read lessmore...
- Flat Roofing
- Roofing general
Brander lane
The client had a recent survey on the property before she brought it and knowing all the underlying problems the poorly installed failing felt roof was causing after she …
Read more
The client had a recent survey on the property before she brought it and knowing all the underlying problems the poorly installed failing felt roof was causing after she brought the property. The client contacted the flat roofing company addressing the problems she had occurred we all agreed the best option to stop any problems in the future and assurance of longevity and performance.
Existing felt roof is failing miserably with sections of blistering water under the felt system that had previously been installed and felt. I find it hard to understand how someone has installed this for a customer.
We done a complete strip off taking it down to the existing joists and insulation these being in pretty good condition considering. New 18mm marine plywood was installed to existing joists and a new opening for skylight created. Evalon VSK was fully adhered to new ply substrate. Old ridge tiles wee taken off and this allowed us to re-ply and membrane the parapet wall. Once completed the existing ridges were installed.
Read less
Witchampton
Recent project finished in witchampton last week. A timber roof created with furring’s on new fantastic timber oak extension, and falls created to minimize any standing …
Read more
Recent project finished in witchampton last week. A timber roof created with furring’s on new fantastic timber oak extension, and falls created to minimize any standing water. A new plywood substrate was installed on existing roof for a great flat finish. Alwitra Evalon VSK single membrane was laid and fully adhered to 18mm plywood deck. Finished with a 125mm water check and 100mm drip detail. Black Ogee style guttering and downpipes were supplied and installed to customers specification. Customer was very happy with the great workmanship, professionalism and left an amazing review.
Read less
Leydene Road
Flat roof area upgrades before + after at 6 Leydene Road.Our client decided to upgrade all the flat roof areas to warm roofs. The old skylight had water coming through it as …
Read more
Flat roof area upgrades before + after at 6 Leydene Road.Our client decided to upgrade all the flat roof areas to warm roofs. The old skylight had water coming through it as well as multiple areas of pooling water becoming a concern. We completed a core sample test to show how much insulation each roof needed to meet the required U-values. The top bedroom roof we installed a tapered insulation scheme and drop down to eradicate any pooling issues. Eva-therm insulation has been bonded to the existing felt roofs with Alwitra Evalon VSK single ply membrane fully adhered to the insulation. The kitchen extension old skylight frame was removed, and a new timber frame was built correctly, and skylight lantern installed once membrane completed. Matching trims all round as well as a new sky lantern supplied by the flat roofing company.
Read less
River way
River way project was a refurbishment of a domestic property with a new side extension in the Christchurch area. We gave the client several different options and different …
Read more
River way project was a refurbishment of a domestic property with a new side extension in the Christchurch area. We gave the client several different options and different systems that suited the client and more importantly being the most cost effective for them. Once all details were confirmed the client agreed they would be insulating the extension from inside. The Roof was completed with 18mm OSB plywood and a 300mm lay board joining the pitch to the flat. A 50 mm drip batten was installed on the outside perimeter to have ample distance for when fascia and gutter is installed. Evalon VSK single ply membrane was fully adhered on to the ply substrate finished with a 100mm water check and 50mm drip detail.
Read less
Salisbury Racecourse
We had the pleasure of installing a warm roof on the new paddock bar at Salisbury racecourse. The ply substrate roof was built with a 1:40 fall with box gutter to meet all …
Read more
We had the pleasure of installing a warm roof on the new paddock bar at Salisbury racecourse. The ply substrate roof was built with a 1:40 fall with box gutter to meet all standard requirements. A polythene BBA certified loose laid vapor control layer firstly installed for condensation purposes and Evatherm 150mm insulation mechanically fixed to stop any potential wind uplift happening. Evalon self-adhered single ply membrane was laid and all laps homogeneously welded. After Drainage calculations were taken 3 x 110mm vertical outlets installed to take the volume of water coming off the cladded roof and newly installed membrane roof.
Read less
House extension- southbourne
House extension 35m2, foil faced self adhered VCL, 140mm insulation and complete with Alwitra Evalon VSK, made to measure outlet chutes and 50mm drip edge to achieve that …
Read more
House extension 35m2, foil faced self adhered VCL, 140mm insulation and complete with Alwitra Evalon VSK, made to measure outlet chutes and 50mm drip edge to achieve that tidy finish for the client. Potential Green roof to be installed at a later date. #construction #theflatroofingcompany
Read less
Cobham- Surrey
A 75m2 new build top roof based in Cobham was completed using 1.2mm thick Evalon VSK self-adhered membrane straight onto 18mm marine ply up. A bespoke 220mm flashing was …
Read more
A 75m2 new build top roof based in Cobham was completed using 1.2mm thick Evalon VSK self-adhered membrane straight onto 18mm marine ply up.
A bespoke 220mm flashing was added on to the tiles and finished with a 50mm drip edge. For a 120m2 hydrotherapy room extension, timber falls were built by others to create adequate falls towards outlet chutes. A mechanically fixed system was used with a loose laid VCL and all joints tapped for the hydrotherapy room. A 120mm PIR tissue faced flat insulation board was mechanically fixed with a sufficient number of fixings complying with regulations. It was completed with Evalon VSK self-adhered membrane up and over parapet walls that were ready for coping stones to be installed.
Read less
Winchester- Millgate construction
Winchester- new build- 170m2 1st plot integrity test complete. Evavap self adhered VCL onto concrete deck. Tapered cut to falls Innobond Insulation scheme. Finished with …
Read more
Winchester- new build- 170m2
1st plot integrity test complete. Evavap self adhered VCL onto concrete deck. Tapered cut to falls Innobond Insulation scheme. Finished with Evalon self-adhered VSK. Composite decking and balustrade still to be installed. Now onto 65m2 garage warm roof installation before plot 2 in March. #icbwaterproofing #Theflatroofingcompany
Read less
Botley- new build- 12m2
Botley- new build- 12m2
Warm roof complete using Evalon VSK self adhered straight onto 18mm ply, insulted underneath for sufficient u- values. Complete with 170mm drip edges onto lead flashing
Roof overlay- kings Park
Roof overlay- Kings Park- 21.11.19 -This failing ashpheltic roof with the gutter deteriorating causing water ingress. - Roof overlay using Alwitra Evalon VSK. - insulated …
Read more
Roof overlay- Kings Park- 21.11.19
-This failing ashpheltic roof with the gutter deteriorating causing water ingress.
- Roof overlay using Alwitra Evalon VSK.
- insulated gutter to make smooth a and neater finish.
- finished with 75mm water check trims
Read less
Flat roof refurb - Canford cliffs
*Flat roof refurb* We recently completed this small project in Poole. The flat roof was leaking and caused a power cut. In 1 day we created a slight pitch using timber …
Read more
*Flat roof refurb*
We recently completed this small project in Poole. The flat roof was leaking and caused a power cut. In 1 day we created a slight pitch using timber furrings and plywood. After insulating the sides we used a single ply membrane to waterproof the area. Just the tiles left to be all new!
This membrane allows us to overlay the existing roof meaning there are no penetrations or openings. Perfect for this time of year!
20 year warranty and full insurances.
Checkatrade Federation of master builders CHASSingle ply roofing association
Please email [email protected] for any enquiries.
Read less
37m2 house extension- curdridge
37m2 house extension- curdridge
- Evalon VSK self adhered membrane strainght to plywood.
- finished with a water check perimeter detail
- drop down gutter complete with outlet chute.
Garage extension- Fleet
20m2 house extension, using Evalon VSK self adhered membrane complete with water check and drip trims, skylight ready for installation #the_flat_roofing_company #singleply @ Church Crookham
New build extension- 48m2
New build 48m2 garage extension in Winchester, Evalon self adhered VSK membrane up and over parapet walls reading for capping to be installed by us The flat roofing company. …
Read more
New build 48m2 garage extension in Winchester, Evalon self adhered VSK membrane up and over parapet walls reading for capping to be installed by us The flat roofing company. 2no skylights complete ready for glass installation. #roofing #the_flat_roofing_company @ Winchester, Hampshire
Read less
Kings park road- Refurb
Kings park road- Refurb Complete Roof and Decking refurb for a client in kings park. -Old decking rip up -Old felt clean up - Felt overlay using Alwitra Evalon VSK. …
Read more
Kings park road- Refurb
Complete Roof and Decking refurb for a client in kings park.
-Old decking rip up
-Old felt clean up
- Felt overlay using Alwitra Evalon VSK.
-Finished with a 75mm drip detail around perimeter.
- Completed with fantastic new decking and wooden balustrade by Burwood carpentry.
#the_flat_roofing_company
Read less
20m2 new build extension- South Wonston
20m2 new build extension- South Wonston - 1.05m self adhered membrane to 18mm plywood - complete with a drop down gutter and 200mm parapet details - 1x outlet chute …
Read more
20m2 new build extension- South Wonston
- 1.05m self adhered membrane to 18mm plywood
- complete with a drop down gutter and 200mm parapet details
- 1x outlet chute created for a great finish through the parapet wall
- zinc detail to be completed on top of parapet walls for a really smart finish- completed by others.
Read less
6m x 0.8m gutter - Winchester
6m x 0.8m gutter - Winchester - Evalon VSK self adhered to 18mm plywood - 75mm drip edge detail into a new hopper. - 100mm water check trim fixed and taped to stop any …
Read more
6m x 0.8m gutter - Winchester
- Evalon VSK self adhered to 18mm plywood
- 75mm drip edge detail into a new hopper.
- 100mm water check trim fixed and taped to stop any gutter water running back over edge
- All laps heat welded to create a 100% water tight seal.
Read less
Sandbanks - 4 year old felt roof completely failed
100m2 refurb and felt overlay - sandbanks - existing felt used as a Vapour control layer - 120 mm insulation adhered with a PU Adhesive so no penetrations through the roof. …
Read more
100m2 refurb and felt overlay - sandbanks
- existing felt used as a Vapour control layer
- 120 mm insulation adhered with a PU Adhesive so no penetrations through the roof.
- 1.2 Evalon VSK self adhered membrane overlaying the 120mm insulation.
- white 75mm drip trims around perimeter of the parapet detail.
For any new builds, refurbs, overlays and green roofs please get in contact with the flat roofing company. https://www.theflatroofingcompany.com/
Read less
Chichester - New 190m2 extension for a residential home
190m2 new build extension- Chichester -polythene loose laid VCL laid onto furrings and 18mm plywood. -120mm tissue faced powedeck insulation mechanically fixed and creating …
Read more
190m2 new build extension- Chichester
-polythene loose laid VCL laid onto furrings and 18mm plywood.
-120mm tissue faced powedeck insulation mechanically fixed and creating a 0.4U value
- Evalon 1.2 VSK self adhered membrane
- 2 skylights
- watercheck and drip detail finish around perimeter edge.
For any new builds, refurbs, felt overlays and green roofs please get in contact with the Flat Roofing Company. https://www.theflatroofingcompany.com/
Read less
Music roof - winchester
New build music room- winchester Evalon VSK 1.2 self adhered membrane straight to 18mm plywood, self adhered membrane creating a perfect aesthetically pleasing finish. …
Read more
New build music room- winchester
Evalon VSK 1.2 self adhered membrane straight to 18mm plywood, self adhered membrane creating a perfect aesthetically pleasing finish. 75mm Water check trims across perimeter creating an innovative way for the travel of water to make its way to the back edge. 50mm drip edge along the guttering edge and all neatly complete with a 100mm cover tape for the perfect finish.
Read less
Green roof - winchester
Green roof - complete in Winchester - layers consist of
. PL 300 Protection fleece
. EvaDrain 25
. FL 150 black Filter fleece
. 300mm pebble border
. 60mm substrate
. Sedum
#greenroof #icb #theflatroofingcompany
new build extension - Botley
35m2 extension. Alwitra Evalon VSK self adhered membrane straight to plywood. Evalon vsk taken up and over skylight and parapet walls ready for coping stones to be …
Read more
35m2 extension.
Alwitra Evalon VSK self adhered membrane straight to plywood.
Evalon vsk taken up and over skylight and parapet walls ready for coping stones to be installed.
2 outlet chutes custom made to the clients specification, perfect for coming through parapets and an aesthetcally pleasing finish.
20 year guarantee.
Read less
Winchester
New build block of flats plot 3-4 Evalon 1.2 VSK self adhered membrane straight to 18mm plywood. Perfect for this project being quick, innovative and great aesthetically. A …
Read more
New build block of flats plot 3-4
Evalon 1.2 VSK self adhered membrane straight to 18mm plywood. Perfect for this project being quick, innovative and great aesthetically.
A 75mm drip edge detail mechanically fixed across perimeter with a neatly welded 100 mm cover strap.
ICB solar fix profiles fully heat welded to the roof and this is a great system because we do not have to penetrate the roof for solar panels to be fitted.
20 year guarantee.
Read less
kingswell Road - Bournemouth
-New build extention and garage 55m2 - alwitra Secutop 1.5mm fleece backed dark grey membrane fully adhered to 18mm marine ply. - secumet 75mm water check trims mechanically …
Read more
-New build extention and garage 55m2
- alwitra Secutop 1.5mm fleece backed dark grey membrane fully adhered to 18mm marine ply.
- secumet 75mm water check trims mechanically fixed at 200mm centres to allow for wind uplift across perimeter with a dark grey finish to match the colour of facias.
- secumet 50mm drip mechanically fixed also at 200mm centres across front gutter edge.
- A very versatile membrane
- 20 year warranty
Read less
canford cliffs road
old failing felt roof-Refurb - removal of exsisting felt. -Replaced damaged plywood with new 18mm plywood. - Evalon VSK slate grey membrane self adhered to 18mm plywood. - …
Read more
old failing felt roof-Refurb
- removal of exsisting felt.
-Replaced damaged plywood with new 18mm plywood.
- Evalon VSK slate grey membrane self adhered to 18mm plywood.
- Evalon coated trims with a slate grey finish to match Evalon VSK roof.
-20 year warranty
-
Read less
Lymington - New build flat roof + Garden summerhouse
Warm Roof Construction - Vapour control layer applied to Plywood - 140mm insulation mechancially fixed on top of Vapour Control Layer - Alwitra Evalon VSK membrane fully …
Read more
Warm Roof Construction
- Vapour control layer applied to Plywood
- 140mm insulation mechancially fixed on top of Vapour Control Layer
- Alwitra Evalon VSK membrane fully adhered to insulation
- Gutter + Outlet created
- 1 Days work with a 20 year warranty issued.
Read less
Ferndown - Full flat roof repair 50m2
Old, failing felt roof. - Remove Felt - Replace damaged plywood with new 18mm plywood. - Full Alwitra Evalon V fleece backed membrane fully adhered to new plywood - …
Read more
Old, failing felt roof.
- Remove Felt
- Replace damaged plywood with new 18mm plywood.
- Full Alwitra Evalon V fleece backed membrane fully adhered to new plywood
- Matching trims around the perimiter on to the face of the fascia
- 20 year warranty
- New look, innovative and effective waterproofing system!
Read less